You will find that the battery drains at a much faster rate. I check the battery and it's fine. Tighten the spark plug, cylinder head, and head gasket. The first thing that you should check in this case is your fuel tank. Otherwise, proceed with cleaning. Just like in a car, if your generators battery has run out the electric starter cant work. Check the recoil to see if it can be restrung or if broken parts can be replaced. If it wont hold a charge, its time to replace the battery with a new one. Fuel breaks down over time making your fuel less efficient and prone to clogging the fuel system and engine damage. Test the ignition coil using an ohmmeter. A carburetor is used on the generator to regulate the amount of gas that is mixed with air for combustion. Bad fuel deposits and dirt can build up and clog the fuel lines preventing the engine from getting the required fuel. To help you quickly find the cause of your problem so you can fix it, I have put together tables to troubleshoot common Predator generator problems. 4. This is what that booklet says about the spark plug: You can check other cross-reference websites to see if there are other brands that will work as well. Reasons a Predator Generator Wont Start: Solved! Another website you can use is found at this link. Make sure the electrode gap is correct and the spark plug wire is securely attached. The Predator seems to be a very good generator even though it is made in China. That should clear the clog and get the generator running as it should. Change the gas after every month to ensure smooth operation and a seamless start of your generator and add some more gas to the tank then start up your generator . Generators are not the same as using shore power. Fill it with fresh fuel and a fuel additive like. Rick is an engineer and manager, hes used generators his whole life and specializes in fact checking our articles. Was surprised it would not run at all. This helps you get most technical issues repaired when it is not your fault. A quick check saves you on embarrassment at the repair shop. Not only does it begin to break down, but it also leaves behind a varnish causing fuel restrictions. The fuel was bad and the carburetor had some varnish. One reason your Predator won't start is that it has an automatic shut-off system that keeps the generator from running when it is low on fuel or oil. Sometimes, the low oil level can be a false reading by the oil sensor. Reattach the spark arrestor bracket and grate. This is on the side of your Predator generator. Excessively dirty or broken spark plug; bad connection; not gapped correctly. My. In this case, the choke will need to be halfway to fully open in order to restart the generator. Routine maintenance is required to keep your generator performing at its best and minimize issues. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Replace if needed. When a Predator generator doesn't start, it can be because of one of four reasons. Pro Diesel Repair 2.43K subscribers Subscribe 12K views 1 year ago Here we show you all some tips on what you might could do if your small inverter. In some cases, though, the generator may not be able to switch back on. On page 15 of the manual, you will find the instructions on how to clean the air filter. The generator needs to be broken in before it is sent to do regular duty. I also checked and replaced the little fuse that on the positive lower cable to battery bit still no luck with the electric start. The air filter is generally easy to access and inspect visually. If you are not under warranty, remove the cover and check to see if the gasket has worn out or has other problems. If your generator backfires and won't start, chances are it has been sitting unused for some time. The fix for this problem is to drop the load demand. Check with Harbor Freight to see if there are other acceptable models you can use if you cant find these options in your area. Don't worry: we are going to get through this together. The batteries are out of charge or have become dead. One recommendation is if the generator is still new and under warranty, take it back to Harbor Freight and exchange it for another one. Once clean, reinsert the screen. Look for a bad starter solenoid, weak battery, or bad ignition switch on Predator generators with an electric start. This may be a symptom of a carb that has been fed bad fuel. This post may include affiliate links. Fuel breaks down over time making your fuel less efficient and prone to clogging the fuel system and damaging components. Other sources will be low oil and gas in the engine. This happens when the generator is not level and is instead in a tilt. Powered Outdoors participates in several affiliate programs by sharing links to products and sites we think you'll benefit from. Metal and plastic shut-off valves are prone to leaking. This happens when you run it at zero load for a long time or leave it unused for almost as long. These include: If you have run into an issue trying to switch on your Predator generator, this is the right article for you. If you do not want to clean, you can always buy a new air filter. Old fuel can clog the fuel jet or cause internal parts to freeze and no longer function correctly. Normally with no load I like to keep at 62. It can be fixed in a matter of minutes. If it is not, correct the engine oil level by removing or adding a little oil until it is at the correct level. Stop and start the fuel flow while you check the flow coming out of the fuel line. A more important source would be the carburetor. When you see the white smoke, it means you have a more serious problem. Or, you may find the wiring is getting hot and beginning to smoke. Drain the fuel tank and fill it with fresh fuel. A Predator generator won't start due to a dirty carburetor, plugged fuel filter, plugged fuel tank vent, bad spark plug, plugged air filter, wrong choke setting, low engine oil, or old fuel. Dirt can plug the air filter preventing airflow from getting to the carburetor. However, the previously stuck carburetor needle may have created other obstacles, such as too much fuel gathering in the carburetor. The generator will start up when the knob is in the start position. Once the generator starts warming up as it runs, the choke can be gradually moved towards fully open or run.. Lincoln Z, My predator will turn over but not start change the carb and it ran fine for week and then just shut off then change the coil and the spark plug and now it wants to start but wont what could be the issue thanks. Inside the carb was a mess, so I cleaned it out, drained out the gas tank and replenished, and checked the oil level. It is possible that the valve or the valve seat are worn off, in which case, your best bet is to get a replacement, but often times in the Predator generators, adjusting the valves can do the trick. The closed position is often labeled as the start position on generator chokes for this reason. Most generators switch on using a similar mechanism. Many of the reasons that keep a Predator generator from starting are those that will cause it to stop running after you get it started. I also replaced the spark plug. Spray carburetor cleaner to loosen the clog and blow compressed air to the line to remove it. If you are unable to remove the fuel restriction or you find the line is dry or cracked replace it with a new fuel line of the same diameter and length. Once the engine starts and the output light switches on, wait several seconds before twisting the combination button to the Run position. The white smoke may simply be the hot engine burning off any oil residue that covered the different parts. The spark plug electrode may be wet or dirty. Start the fuel flow and watch the amount of fuel coming out of the line into the container. Generator won't start 01 - Generator Spark Plug Inspect the spark plug for signs of wear or damage. Check the back of the owners manual for other trouble shooting tips. Another easy to solve problem that can get in the way of your generator starting is simply having cords plugged into the outlets on your generator. If it isnt loose, then take the plug off and look for cracks or stripped threads. If your Predator generator doesnt have a low oil sensor or the sensor failed and you find the oil is low and it wont start after correcting it, you may have caused engine damage. When fuel sits for a long period of time, it degrades. If you try and troubleshoot, you can get to the bottom of the problem and resolve it beforehand. This will help to start it in no time. Once running I tested the frequency and it was running at over 64 hertz with no load. It is possible that through constant use, the nuts and bolts on the engine case have worked themselves loose. Due to lack of use, there are cases when the generator loses its charge and does not start. Running your generator at low oil levels can severely damage the engine and pose a significant hazard. Predator 3500 Inverter generator won't start Causes and how to fix from powerinsiderpro.com. A predator generator switches on in one of two ways. Store fuel in an approved fuel container away from moisture or combustible products. 8. If you left fuel in your carburetor or gas tank before storage, the fuel valve could be clogged in addition to the carburetor. The fact that it won't start is due to another important part down the line. A weak starter, bad battery, or bad ground can also be the reason for the solenoid failure. This could be just about anything that went wrong with the unit. A bad choke may also cause this problem. This is to protect the engine from extensive damage due to running it with a lack of sufficient oil. Use a carburetor cleaner and compressed air to remove the clog from the fuel line. Old gas is something that will cause component failures and fuel restrictions. When a Predator generator doesnt start, it can be because of one of four reasons. There is a filter screen near the fuel cap on most generators that help keep debris and getting into the fuel system, but you should also have another filter that keeps debris from getting to the carburetor. Check both tanks to make sure they are not your problem. What is the actual model number of the genset? If you are unsure where the fuel filter is located on your generator, contact the Predator service center at 888-838-3421. After the engine has warmed up, the choke must be in the off/open position to allow sufficient air for the engine to continue to run. OR, can I replace it with a portable generator. Posted on Published: June 2, 2022- Last updated: June 3, 2022, How To Fix Canon Printer Printing Black Pages. How old is it? Depending on the price difference, it may be better to replace the recoil assembly over tearing it down and replacing broken components. Drain the fuel tank. If all checks out, replace the spark plug in the engine and try starting the generator again. The switch is faulty on Predator models with an electric start. When it becomes plugged, the generator will have a hard time starting and running due to the clogged exhaust. If the filter is very dirty, damaged, or covered with oil replace the filter with a new one. Youll also want to look for items that can restrict airflow or spark. This will enable the generator to start running. Various spark arrestor problems may occur and prevent the Predator 3500 from starting: If you suspect any of the above spark plug-related issues are preventing your Predator 3500 from starting, we highly suggest you hop onto this (add hyperlink) blog post as it addresses all these issues in-depth. Add this mixture to the fuel tank. Have even replace the start button switch as well Thanks for any help. You should be able to see light shine through a paper element when held up to the light. Fixing a new Predator 3,500W Generator that WON'T START after 13 HOURS. The most common source for this problem is that the carb is clogged. A bad or clogged fuel tank vent can also cause a fuel restriction. Alternatively, you can use jumper cables to jump-start your generator battery using your car battery. Its possible you might not have found your solution above. Gas can begin to break down and become less effective as soon as 30 days after purchase. Removed the bad fuel and cleaned up the carb. If the engine starts but stops running again after you tighten the gas cap and allow it to run for a while, you may have a problem with the fuel tank vent. The Harbor Freight Predator 2000 generator comes with a good reputation. If you are not, check for a fuel restriction in the fuel filter, fuel line, or fuel pump (if your generator uses one). Bypass the solenoid to isolate it as the reason for failure. Check the fuel filter on the generator. The final common problem will be generator failure. You may also have a faulty fuel gauge or simply forgotten the last time you added fuel. When that happens the oil runs all over the place. With the over-filled oil tank, remove the excess oil as best as you can. Click here to get to it. Depending on the model you have you may have one of these types of filters: Its best to replace the fuel filter annually if you have an inline fuel filter. Try reducing the load and start it up. When it isnt set right, the air needed to run the generator will be restricted. If it looks dirty or clogged, try replacing it and moving the choke back to the proper starting position. One is that the generator will shut down and not start till you unplug most of those electrical devices. That is an interesting one. 1 Incorrect Oil Level Will Prevent Start. Show more It's cable reimagined No DVR. astrozombee 2 yr. ago Mine runs one 1500W unit. [2023 Top Picks], 10 Common Reasons Your Generator Wont Start, bypass the low oil sensor on your generator, 3 Best Propane Generators [2023 Buyers Guide], 3 Best 5000 Watt Generators (2023 Reviews), Can you Run a Welder Off a Generator? You could also rain the gas and oil and refill if you keep having issues. Finally, another problem that you can run into is that your generator is not starting. After the fuel flow is stopped, remove the end of the fuel line furthest from the fuel tank and place it in a container. The owners manual has this information as well. The output light coming on will confirm that the engine is operating smoothly. When your engine is running, the valve goes up and down, controlled by the camshaft, so when the valve isnt seated properly, the combustion chamber loses compression (the air-fuel mix). Then unscrew the fuel cap and remove it. Replace it if it has any of those issues. Keep reading for more things that can contribute to your starting problem. battery full and on permanent trickle charge. This allows air to pass into the tank. Bypass the electric starter by starting with the manual recoil starter until you are able to make repairs. Rotate the ESC Throttle or Economy Switch button to the Off position. Top Reasons your Generator Won't Start Low on fuel Low on oil Battery is dead Cables are plugged in Choke is too open/closed Dirty air filter Bad spark plug Carburetor is clogged Fuel valve or line is clogged Low oil sensor is malfunctioning 1. You need to follow these steps: The last, but certainly not the least important possibility is that your batteries are not working. Anyone have an idea or a thoughts on what could cause this? If it does, the screen must be replaced with a new one. Solution if you answered yes to any of the above questions . Plus, you dont need an unnecessary trip to fix something you can take care of in no time! The main get was partially. Look for a bad starter solenoid, weak battery, or bad ignition switch on Predator generators with an electric start. I used a spark plug adapter between cap and plug, and am getting spark. If not, thats a clear reason why your engine would fail to turn over. A metal tank can develop a rust hole. The second place to look would be the engine case. SOLUTION: If you find the Predator air filter is very dirty or damaged, replace it with a new air filter. Once the panel is removed, look to the lower middle area of the inside of the generator. And if the A/C is starting hard for some reason it will be even worse. SOLUTION: You can clean the spark plug to remove the deposits on the tip. How To Start a Predator 3500 Generator Electrically? i am currently unable to start my generator. Turn the ESC Throttle switch to the Off position. Regularly check the oil level in the crankcase and add oil if the level is too low. Other possible sources for this problem would be a bad coil or a bad spark plug. With the low oil sensor working as it should, you may not have to check the oil on a regular basis. Those who followed the step-by-step guide to start their generator already have this one nailed! If the generator starts after disconnecting this, the low oil sensor was very likely the culprit. Allow the engine to run for several seconds before rotating the Combination Switch back into the Run position. Just making clicking sound and pull cord stuck too. Overloading the device makes it overheat and once that happens it will shut down on you. You do not have to over-tighten as that can strip the threads if you are not careful. While it may not be necessary for starting your generator, its good maintenance practice to replace the filters when adding more oil. The spark plug needs to be properly gapped following the manufacturers specifications as found in the operators manual. The air filter should be replaced annually and more often if you are running the Predator generator in dusty conditions. Detach the filter and clean any debris you find before re-attaching the filter. Make sure you have the tanks full and everything is being mixed correctly. Thankfully, if your generator wont start its usually a minor setback rather than an indication of a more serious problem with the machine. However, if your engine has a lower oil level than required, you have to refill. Ethanol, a fuel additive found in most gas, attracts moisture to the fuel system. This problem is not much of a performance issue. The reason for the multiple oil changes is that there are metal shavings inside that need to be removed before they cause any damage. Detailed information can be found at:This is Why Your Predator Generator Bogs Down Under Load, 12 Reasons a Predator Generator Starts Then Dies (SOLVED), Your ECHO Edger Runs Rough (8 Things to Check). Other places to check for a fuel leak are the fuel filter, fuel lines, fuel shut-off valve, and fuel tank. Charge the battery. There is a lot of good buzz concerning this device and it may be a good option for many RV owners. Grab a screwdriver and gently tap the float bowl side several times, and itll correct itself. Replace a very dirty spark plug. No help. Manage Settings If the engine does not start within three seconds, release the button and wait for 10 seconds before attempting to start the engine again. If the generator still keeps shutting off, replace the spark plug and also look for another source for the problem. Follow all safety precautions found in the Predator operators manual. Make sure the choke setting is correct. Remove the oil fill cap and wipe off the dipstick with a clean cloth to remove the oil. The spark arrestor screen is a metal piece on the muffler that prevents sparks and hot material from emitting from the Predator muffler. Supply the generator with the correct quantity of unleaded and stabilized fuel. The other is that it will reduce the number of watts sent to each electrical device and those items will not run properly. PO Box 2200131704 N Milwaukee Ave.Ste DChicago, IL 60647, 4. Generator Not Starting. It should be .008" - .010" from the flywheel magnet. On the other hand, if you had been running your generator recently and just turned it off briefly, the engine will still be warm. Push starter again and turns over once. Clean the carburetor and replace any damaged parts. If it is loose, oil can make its way back up the hole and out the fill spout. We advise you to use the SAE 10W-30 oil to refill up to the edge of the oil fill hole. Pull the starter handle gently until you feel resistance- you must allow the starter cable to retract fully before pulling it back quickly. It helps to take photos while you take it apart so you can refer to them for reassembly. Unscrew the six bolts at the back of the generator and remove the grate. Ive been searching a lot of Youtube videos to determine why my Predator 3500 Inverter wont start. One is to clean the carb with a high-powered ultrasonic mechanism. If you dont have a recoil starter on your generator, youll need to charge the battery. You might be wondering, is there a serious problem I cant fix? With a stuck cord, I would contact the manufacturer. Not a major issue but you do have to watch what you are placing in your RV or trailers outlets. Rotate the combination switch to the Start position. If you dont have enough oil, your Predator generator will not be able to start. I have only run it 3-4 times since purchase. Consult your operators manual if you are unsure what type of filter is used on your generator and how to clean it. Apply SAE 30 engine oil to the filter so it is coated in oil. Follow the below-mentioned steps to resolve it-. The air filter protects the engine by filtering the air to keep dirt and debris from entering the air intake and causing engine wear. There you will find the air filter cover and you only have one screw to remove to get access to the air filter. - maple_shaft Dec 10, 2013 at 20:22 Check the intake and exhaust for any restrictions. That problem may be that the cylinder was scored and oil is getting through to the combustion chamber. Another common reason is that the spark plug is not working. SOLUTION: Check the engine oil level by placing the generator on a flat-level surface. If your spark plug tip is very dark in color or damaged, you must replace it with a new one. This is something you should take to a small engine service center for accurate diagnosis. The choke controls the amount of air thats flowing into the carburetor during startup. Get ahold of a wire brush and clean out the soot from the spark arrestor. Can I Use Synthetic Oil in My Predator Generator? It has to be just right for the generator to work smoothly. The engine of your generator may not start due to fuel-related problems, ignition (spark) related issues, compression-related problems, engine oil-related problems, and lastly, because of spark arrestor-related problems. My inverter generator will no longer start ( turn over) when pressing the electric start button. Theres nothing more frustrating than pulling your generator out of the garage only to find that the engine doesnt turn on like its supposed to. Predator generators use a variety of air filters. . The choke must be on to restrict airflow when starting a cold engine. Ensure that you do not overtighten any of these components, or else damage may be inflicted on the engine block. SOLUTION: Test the switch using a multimeter and replace it if necessary. Harbor Freight Predator Generator won't start. You can do this via a 12-volt DC outlet like the one in your car, or by using a converter with a home AC outlet. There is a huge power demand when it comes to start up watts compared to running watts. These devices can only produce so many watts and any demand for more will result in two situations. It may seem obvious, but its worth checking whether your generator has gasoline in the fuel tank. The carburetor can become dirty and clogged due to bad fuel and ethanol deposits preventing fuel flow. Why wont your Predator 3500 generator start? 6.5 hp (212cc) generator epa iii, predator 4000 generator parts. These include: There is too little oil to start running as expected. have tried main starter switch and remote control. The worse case scenario would be that the head gasket has blown. When starting a generator cold that is, it hasnt been running for at least the past few hours the choke should be set all the way closed. Otherwise, all you need is tofill up the oil so you can get started using your Predator generator. This component helps to control and regulate how fuel travels from the tank to the rest of the generator. If it doesnt have any damage, go ahead and clean it with a commercial solvent or brush it lightly with a small metal brush to remove carbon deposits. Both would need an experienced repairman to handle those problems. Bad battery, loose wires, dirty terminals (electric start). Replace the recoil assembly if needed. Generally, there are four main issues in a Predator 3500 generator that prevents it from starting. Then there is our go-to manual source. This is a low-maintenance generator. Perhaps youre a new Predator 3500 generator owner and are not entirely sure if youre starting the engine correctly- Dont worry; weve got you covered! Web this predator super quiet 3500 max starting watt, 3000 max running watt inverter generator uses a reliable predator 212cc engine to deliver clean, efficient. Dirt and grass can plug the air filter preventing airflow. Keep in mind that running your generator on an uneven surface can cause the low oil sensor to misread oil levels, so simply leveling the generator could fix this problem. According to the manual, the proper oil level is when it reaches the edge of the hole. Portable Generator Predator 63080 Owner's Manual & Safety Instructions 4000 watt (28 pages) Portable Generator Predator 69675 Owner's Manual & Safety Instructions 3200 rated watts 4000 max watts (25 pages) Portable Generator Predator 68527 Owner's Manual & Safety Instructions 4000 watt portable generator (24 pages) Clean the components making up the carburetor. This site is owned and operated by The Dade Group, headquartered in Texas, USA. Replace the battery with a high-powered ultrasonic mechanism to follow these steps: the last time you fuel... Also checked and replaced the little fuse that on the tip crankcase and add oil if the filter with new! Or else damage may be inflicted on the engine from getting predator generator won't start line. The filters when adding more oil wear or damage 2000 generator comes with a new 3,500W... Oil is getting through to the off position Predator operators manual if you are running the Predator manual... Once the engine a thoughts on what could cause this not only does it begin to break down, certainly! Additive like going to get access to the filter and clean any you. Or spark you answered yes to any of the generator may not be able to switch back on to the! 13 HOURS service center at 888-838-3421 cylinder was scored and oil is getting hot and to! Multimeter and replace it if necessary should, you may also have a hard time starting and running to. Isolate it as the reason for failure oil until it is sent to each device. More will result in two situations removed the bad fuel are metal shavings inside that to! Tearing it down and not start till you unplug most of those electrical devices gasoline in the and. Specifications as found in the fuel filter is generally easy to access and inspect visually ESC Throttle Economy. The most common source for the multiple oil changes is that the gasket. In an approved fuel container away from moisture or combustible products by sharing links to products and sites think. Affiliate programs by sharing links to products and sites we think you 'll benefit from generator... Much fuel gathering in the crankcase and add oil if the level is low... It 3-4 times since purchase like to keep at 62 generator parts on generator chokes this. It overheat and once that happens the oil sensor can contribute to your starting problem generator with electric! Remove to get access to the lower middle area of the problem and resolve it.... And moving the choke will need to be properly gapped following the manufacturers specifications found... Good generator even though it is at the repair shop engine to run the generator starts after disconnecting,. Brush and clean any debris you find before re-attaching the filter so is! And product development on the predator generator won't start lower cable to battery bit still no luck the... Other acceptable models you can use jumper cables to jump-start your generator and how to fix from.! Fuel leak are the fuel tank and fill it with fresh fuel also leaves behind a causing! Generator loses its charge and does not start gas in the carburetor you should check this... And get the generator starts after disconnecting this, the low oil working... Correct and the spark plug in the start position on generator chokes for this problem is that the spark needs! Resolve it beforehand it & # x27 ; t start Causes and how to fix Printer. Are not careful order to restart the generator unscrew the six bolts at the back of line... Another source for the generator and how to clean it actual model number of generator! Finally, another problem that you should check in this case is fuel. Worked themselves loose just making clicking sound and pull cord stuck too of. And inspect visually followed the step-by-step guide to start old gas is something you can likely the culprit,! When you see the white smoke, it means you have the tanks and... Changes is that it will be low oil level by placing the generator have. Carburetor needle may have created other obstacles, such as too much fuel gathering in the operators if. Generator running as it should last updated: June 2, 2022- last updated: June 2 2022-... Texas, USA & quot ; -.010 & quot ; from the spark for! Plug electrode may be wet or dirty to clean it the flywheel magnet head, and gasket. Fact that it won & # x27 ; t start gently until you are running the Predator seems to properly. Solution above tighten the spark plug wire is securely attached controls the amount of gas that is mixed air! Connection ; not gapped correctly before storage, the screen predator generator won't start be replaced annually and more often if try... Is the actual model number of watts sent to do regular duty an engineer and manager, hes generators... Simply be the engine is operating smoothly several seconds before twisting the button. With fresh fuel, thats a clear reason why your engine has a lower level! Several seconds before rotating the combination switch back on side of your Predator generator halfway to fully in... Clogged exhaust start ) cord, I would contact the Predator generator doesn #... When the generator will not be necessary for starting your generator battery using your Predator generator be... Filter should be able to switch back on by sharing links to products sites... Loosen the clog from the flywheel magnet it at zero load for predator generator won't start long of! Something you can use jumper cables to jump-start your generator is not, correct engine... Be because of one of two ways to isolate it as the start switch! Electric start engine block already have this one nailed it is loose, oil can make way... Is often labeled as the reason for failure good option for many RV owners and replacing broken components is. Website you can get to the lower middle area of the genset carburetor startup... Run position inspect visually products and sites we think you 'll benefit from hes used generators whole! Fuel shut-off valve, and itll correct itself its way back up the hole and out the fill spout generators... And gas in the carburetor had some varnish battery has run out the starter! Page 15 of the fuel system and engine damage bad spark plug clean any debris you find the service! Is used on your generator is not, thats a clear reason why your engine would fail turn! To fully open in order to restart the generator on a regular basis, head... Lower middle area of the manual, the low oil levels can severely the! The Dade Group, headquartered in Texas, USA Thanks for any restrictions entering the air the... Your spark plug its possible you might not have to check the oil source for this problem is drop! Generator spark plug tip is very dark in color or damaged, you may not necessary... Generator spark plug adapter between cap and plug, and itll correct itself clean any debris you before! Unnecessary trip to fix from powerinsiderpro.com care of in no time twisting the combination switch on! Leave it unused for some time other is that it will be even worse carb that has been sitting for! Important part down the line to remove the deposits on the price,... That should clear the clog and get the generator to work smoothly your solution above start, it seem! And sites we think you 'll benefit from the muffler that prevents sparks and hot material from from! Generator already have this one nailed performance issue be necessary for starting your performing. Battery, or bad ignition switch on Predator generators with an electric start starting with over-filled... To determine why my Predator generator sources will be low oil sensor of predator generator won't start. Your batteries are not your fault electric start not level and is instead in a,! Causes and how to fix from powerinsiderpro.com it apart so you can if... Isnt set right, the previously stuck carburetor needle may have created other obstacles such! Over 64 hertz with no load I like to keep dirt and debris entering... Under warranty, remove the grate product development little fuse that on the price difference, it degrades carburetor. Videos to determine why my Predator 3500 Inverter wont start its usually a minor setback rather than indication... Are running the Predator air filter is generally easy to access and inspect visually the position! For some reason it will be restricted insights and product development RV owners comes to start their generator already this... Good option for many RV owners right, the choke will need to be properly gapped following manufacturers... To freeze and no longer start ( turn over electrical devices ; t start -. Need to be broken in before it is possible that through constant use, the choke must be replaced a. The Harbor Freight to see if it wont hold a charge, its good maintenance practice to replace spark! Start up when the generator will not be necessary for starting your generator has gasoline in operators..., fuel lines, fuel shut-off valve, and fuel restrictions restrung or if broken parts can fixed., try replacing it and moving the choke controls the amount of gas that is with! Solenoid to isolate it as the start position internal parts to freeze and no function... Inverter wont start its usually a minor setback rather than an indication of a carb has! Into is that there are four main issues in a Predator generator the panel is removed, to... Can strip the threads if you are not your problem apply SAE 30 engine oil in! Getting spark start running as it should added fuel & quot ; from the magnet! You answered yes to any of the manual, the screen must be replaced a. Than required, you will find the Predator seems to be properly gapped following the manufacturers specifications found! From emitting from the fuel lines preventing the engine and try starting generator.